Brand |
HELIAX® |
Product Type |
Wireless and radiating connector |
|
Interface |
7-16 DIN Female |
Body Style |
Straight |
Mounting Angle |
Straight |
Ordering Note |
CommScope® standard product (Global) |
|
Connector Impedance |
50 ohm |
Operating Frequency Band |
0 – 7500 MHz |
Cable Impedance |
50 ohm |
3rd Order IMD, typical |
-120 dBm @ 910 MHz |
3rd Order IMD Test Method |
Two +43 dBm carriers |
RF Operating Voltage, maximum (vrms) |
884.00 V |
dc Test Voltage |
2500 V |
Outer Contact Resistance, maximum |
1.50 mOhm |
Inner Contact Resistance, maximum |
0.80 mOhm |
Insulation Resistance, minimum |
5000 MOhm |
Average Power |
1.0 kW @ 900 MHz |
Peak Power, maximum |
15.60 kW |
Insertion Loss, typical |
0.05 dB |
Shielding Effectiveness |
-110 dB |
|
Click on image below to enlarge.
|
|
|
|
Outer Contact Attachment Method |
Self-flare |
Inner Contact Attachment Method |
Captivated |
Outer Contact Plating |
Trimetal |
Inner Contact Plating |
Silver |
Attachment Durability |
25 cycles |
Interface Durability |
500 cycles |
Interface Durability Method |
IEC 61169-4:9.5 |
Connector Retention Tensile Force |
890 N | 200 lbf |
Connector Retention Torque |
5.42 N-m | 48.00 in lb |
Insertion Force |
200.17 N | 45.00 lbf |
Insertion Force Method |
IEC 61169-1:15.2.4 |
Pressurizable |
No |
|
Nominal Size |
1/2 in |
Diameter |
28.96 mm | 1.14 in |
Length |
50.01 mm | 1.97 in |
Weight |
150.00 g | 0.33 lb |
|
Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Storage Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth |
1 m |
Immersion Test Mating |
Mated |
Immersion Test Method |
IEC 60529:2001, IP68 |
Water Jetting Test Mating |
Mated |
Water Jetting Test Method |
IEC 60529:2001, IP66 |
Moisture Resistance Test Method |
MIL-STD-202F, Method 106F |
Mechanical Shock Test Method |
MIL-STD-202F, Method 213B, Test Condition C |
Thermal Shock Test Method |
MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C |
Vibration Test Method |
MIL-STD-202F, Method 204D, Test Condition B |
Corrosion Test Method |
MIL-STD-1344A, Method 1001.1, Test Condition A |
|
Attenuation, Ambient Temperature |
20 °C | 68 °F |
Average Power, Ambient Temperature |
40 °C | 104 °F |